All language subtitles for Film 29 Working with air-termination tips

af Afrikaans
ak Akan
sq Albanian
am Amharic
ar Arabic
hy Armenian
az Azerbaijani
eu Basque
be Belarusian
bem Bemba
bn Bengali
bh Bihari
bs Bosnian
br Breton
bg Bulgarian
km Cambodian
ca Catalan
ceb Cebuano
chr Cherokee
ny Chichewa
zh-CN Chinese (Simplified)
zh-TW Chinese (Traditional)
co Corsican
hr Croatian
da Danish
nl Dutch
en English
eo Esperanto
et Estonian
ee Ewe
fo Faroese
tl Filipino
fi Finnish
fr French
fy Frisian
gaa Ga
gl Galician
ka Georgian
de German
el Greek
gn Guarani
gu Gujarati
ht Haitian Creole
ha Hausa
haw Hawaiian
iw Hebrew
hi Hindi
hmn Hmong
hu Hungarian
is Icelandic
ig Igbo
id Indonesian
ia Interlingua
ga Irish
it Italian
ja Japanese
jw Javanese
kn Kannada
kk Kazakh
rw Kinyarwanda
rn Kirundi
kg Kongo
ko Korean
kri Krio (Sierra Leone)
ku Kurdish
ckb Kurdish (Soranî)
ky Kyrgyz
lo Laothian
la Latin
lv Latvian
ln Lingala
lt Lithuanian
loz Lozi
lg Luganda
ach Luo
lb Luxembourgish
mk Macedonian
mg Malagasy
ms Malay
ml Malayalam
mt Maltese
mi Maori
mr Marathi
mfe Mauritian Creole
mo Moldavian
mn Mongolian
my Myanmar (Burmese)
sr-ME Montenegrin
ne Nepali
pcm Nigerian Pidgin
nso Northern Sotho
no Norwegian
nn Norwegian (Nynorsk)
oc Occitan
or Oriya
om Oromo
ps Pashto
fa Persian
pl Polish
pt-BR Portuguese (Brazil)
pt Portuguese (Portugal)
pa Punjabi
qu Quechua
ro Romanian
rm Romansh
nyn Runyakitara
ru Russian
sm Samoan
gd Scots Gaelic
sr Serbian
sh Serbo-Croatian
st Sesotho
tn Setswana
crs Seychellois Creole
sn Shona
sd Sindhi
si Sinhalese
sk Slovak
sl Slovenian
so Somali
es Spanish
es-419 Spanish (Latin American)
su Sundanese
sw Swahili
sv Swedish
tg Tajik
ta Tamil
tt Tatar
te Telugu
th Thai
ti Tigrinya
to Tonga
lua Tshiluba
tum Tumbuka
tr Turkish
tk Turkmen
tw Twi
ug Uighur
uk Ukrainian
ur Urdu
uz Uzbek
vi Vietnamese
cy Welsh
wo Wolof
xh Xhosa
yi Yiddish
yo Yoruba
zu Zulu
Would you like to inspect the original subtitles? These are the user uploaded subtitles that are being translated: 1 00:00:00,000 --> 00:00:15,760 In this tutorial, I will demonstrate how to work with air termination tips. 2 00:00:15,760 --> 00:00:22,200 To be able to install the air termination tips, I already prepared a building with a 3 00:00:22,200 --> 00:00:33,240 saddled roof, an earthing system, a mesh and a cable segment along the ridgeline. 4 00:00:33,240 --> 00:00:42,560 In a second drawing, I prepared a flat roof with a parapet, a mesh and an earthing system. 5 00:00:42,560 --> 00:00:48,360 Let's start with the saddled roof and placing the air termination tip on the cable segment 6 00:00:48,360 --> 00:00:51,900 of the ridgeline. 7 00:00:51,900 --> 00:00:58,580 Using this icon, we can choose between three different commands. 8 00:00:58,580 --> 00:01:05,980 We can position the air termination tip with a 45° bending angle vertically on the conductor, 9 00:01:05,980 --> 00:01:11,419 so in other words from the cable 90° up. 10 00:01:11,419 --> 00:01:18,220 Or with a 90° bending angle laterally on the conductor, so in other words with a 45° 11 00:01:18,220 --> 00:01:23,900 angle facing outside or inside. 12 00:01:23,900 --> 00:01:33,419 Or with a 90° bending angle vertically on the conductor, so from the cable 90° upwards. 13 00:01:33,419 --> 00:01:44,779 Let's choose the first option, 45° bending angle sitting at 90° on the conductor. 14 00:01:44,779 --> 00:01:52,260 In general, we have the option to place the air termination tip directly on the conductor 15 00:01:52,260 --> 00:01:58,059 or we use it to extend the conductor by placing the air termination tip on the end of the 16 00:01:58,059 --> 00:02:03,260 cable segment. 17 00:02:03,260 --> 00:02:11,059 We end the command by clicking left and place the air termination tip. 18 00:02:11,059 --> 00:02:20,419 Here we can see the 45° bending angle. 19 00:02:20,419 --> 00:02:27,100 It's helpful that the arrestor point is already shown here. 20 00:02:27,100 --> 00:02:31,520 Should the cable routing be changed, we can directly see if the arrestor point is still 21 00:02:31,520 --> 00:02:37,820 in its correct place and adapt it if necessary. 22 00:02:37,820 --> 00:02:49,699 Let's change to the second drawing and choose the command 90° angle with a 45° bending 23 00:02:49,699 --> 00:02:58,220 to the outside. 24 00:02:58,220 --> 00:03:03,539 By moving the mouse cursor, we can choose if we want to place the air termination tip 25 00:03:03,860 --> 00:03:16,419 facing outside or facing inside. 26 00:03:16,419 --> 00:03:22,259 Here we can see the 90° bending angle. 27 00:03:23,259 --> 00:03:34,380 Lastly, we choose the command 90° angle placed vertically, so 90° on the conductor. 28 00:03:34,380 --> 00:03:39,539 For all three commands, we can choose if we want to place the air termination tip somewhere 29 00:03:39,539 --> 00:03:51,300 on the inner mesh or if we place it, like in this example, on the conductor on the parapet. 30 00:03:51,339 --> 00:03:56,979 Then we can see the 90° bending angle. 31 00:03:56,979 --> 00:04:01,339 Should we encounter problems while placing the air termination tip on the cable segment 32 00:04:01,339 --> 00:04:08,779 of the parapet, we should check if we defined the risk areas for the parapet appropriately. 33 00:04:08,779 --> 00:04:10,699 That's it for this tutorial. 34 00:04:10,699 --> 00:04:11,539 Thanks for watching. 3392

Can't find what you're looking for?
Get subtitles in any language from opensubtitles.com, and translate them here.