Afrikaans
Akan
Albanian
Amharic
Arabic
Armenian
Azerbaijani
Basque
Belarusian
Bemba
Bengali
Bihari
Bosnian
Breton
Bulgarian
Cambodian
Catalan
Cebuano
Cherokee
Chichewa
Chinese (Simplified)
Chinese (Traditional)
Corsican
Croatian
Danish
Dutch
English
Esperanto
Estonian
Ewe
Faroese
Filipino
Finnish
French
Frisian
Ga
Galician
Georgian
German
Greek
Guarani
Gujarati
Haitian Creole
Hausa
Hawaiian
Hebrew
Hindi
Hmong
Hungarian
Icelandic
Igbo
Indonesian
Interlingua
Irish
Italian
Japanese
Javanese
Kannada
Kazakh
Kinyarwanda
Kirundi
Kongo
Korean
Krio (Sierra Leone)
Kurdish
Kurdish (Soranî)
Kyrgyz
Laothian
Latin
Latvian
Lingala
Lithuanian
Lozi
Luganda
Luo
Luxembourgish
Macedonian
Malagasy
Malay
Malayalam
Maltese
Maori
Marathi
Mauritian Creole
Moldavian
Mongolian
Myanmar (Burmese)
Montenegrin
Nepali
Nigerian Pidgin
Northern Sotho
Norwegian
Norwegian (Nynorsk)
Occitan
Oriya
Oromo
Pashto
Persian
Polish
Portuguese (Brazil)
Portuguese (Portugal)
Punjabi
Quechua
Romanian
Romansh
Runyakitara
Russian
Samoan
Scots Gaelic
Serbian
Serbo-Croatian
Sesotho
Setswana
Seychellois Creole
Shona
Sindhi
Sinhalese
Slovak
Slovenian
Somali
Spanish
Spanish (Latin American)
Sundanese
Swahili
Swedish
Tajik
Tamil
Tatar
Telugu
Thai
Tigrinya
Tonga
Tshiluba
Tumbuka
Turkish
Turkmen
Twi
Uighur
Ukrainian
Urdu
Uzbek
Vietnamese
Welsh
Wolof
Xhosa
Yiddish
Yoruba
Zulu
In this tutorial, I will demonstrate how to work with air termination tips.
To be able to install the air termination tips, I already prepared a building with a
saddled roof, an earthing system, a mesh and a cable segment along the ridgeline.
In a second drawing, I prepared a flat roof with a parapet, a mesh and an earthing system.
Let's start with the saddled roof and placing the air termination tip on the cable segment
of the ridgeline.
Using this icon, we can choose between three different commands.
We can position the air termination tip with a 45° bending angle vertically on the conductor,
so in other words from the cable 90° up.
Or with a 90° bending angle laterally on the conductor, so in other words with a 45°
angle facing outside or inside.
Or with a 90° bending angle vertically on the conductor, so from the cable 90° upwards.
Let's choose the first option, 45° bending angle sitting at 90° on the conductor.
In general, we have the option to place the air termination tip directly on the conductor
or we use it to extend the conductor by placing the air termination tip on the end of the
cable segment.
We end the command by clicking left and place the air termination tip.
Here we can see the 45° bending angle.
It's helpful that the arrestor point is already shown here.
Should the cable routing be changed, we can directly see if the arrestor point is still
in its correct place and adapt it if necessary.
Let's change to the second drawing and choose the command 90° angle with a 45° bending
to the outside.
By moving the mouse cursor, we can choose if we want to place the air termination tip
facing outside or facing inside.
Here we can see the 90° bending angle.
Lastly, we choose the command 90° angle placed vertically, so 90° on the conductor.
For all three commands, we can choose if we want to place the air termination tip somewhere
on the inner mesh or if we place it, like in this example, on the conductor on the parapet.
Then we can see the 90° bending angle.
Should we encounter problems while placing the air termination tip on the cable segment
of the parapet, we should check if we defined the risk areas for the parapet appropriately.
That's it for this tutorial.
Thanks for watching.