In this video tutorial, I will show you how to adjust the standard lightning protection
2
00:00:15,440 --> 00:00:17,600
settings.
3
00:00:17,600 --> 00:00:23,180
In this example, I will change the settings for the currently open project.
4
00:00:23,180 --> 00:00:28,480
If you want to make changes to the standard settings that are valid for several projects,
5
00:00:28,480 --> 00:00:32,619
you can create different templates in DIN project.
6
00:00:32,619 --> 00:00:38,220
Once you create a new drawing, you can then choose between the different templates.
7
00:00:38,220 --> 00:00:45,459
More information on that can be found in the DIN project tutorial on managing templates.
8
00:00:45,459 --> 00:00:52,180
You can open the lightning protection options by clicking on the icon with the red lightning.
9
00:00:53,180 --> 00:00:59,959
Here you can define the distance for the disconnection point above turf, which is currently set
10
00:00:59,959 --> 00:01:05,320
at 80 cm.
11
00:01:05,320 --> 00:01:20,279
In the accessories tab, you can adjust the material that is used above the turf
12
00:01:20,279 --> 00:01:36,760
and below turf, adapt the used material and product types.
13
00:01:36,760 --> 00:01:43,699
By selecting this checkmark, you can choose to use numbered disconnection point tags.
14
00:01:43,699 --> 00:01:50,339
A deselection means that the numbered disconnection point tags are replaced by blank tags that
15
00:01:50,339 --> 00:01:55,779
can be numbered with inserts afterwards.
16
00:01:55,779 --> 00:01:59,940
Let's move to the visibility tab.
17
00:01:59,940 --> 00:02:05,820
Here you can choose which components in your model or in the viewport should be displayed
18
00:02:05,820 --> 00:02:08,580
as standard.
19
00:02:08,580 --> 00:02:14,380
The viewport will be important at a later stage for the dimensioning of your plan.
20
00:02:14,380 --> 00:02:21,020
I will explain that in an extra tutorial.
21
00:02:21,020 --> 00:02:28,139
The lightning protection components tab enables you to define your pre-settings for the usage
22
00:02:28,139 --> 00:02:40,419
of various conductor holders and clamps for the respective planning method.
23
00:02:40,419 --> 00:02:45,899
For the isolated protection method, you have the option to further choose between the different
24
00:02:45,899 --> 00:02:51,220
variants.
25
00:02:51,220 --> 00:02:59,020
According to the earth termination system tab, we have the option to adjust the mesh
26
00:02:59,020 --> 00:03:09,779
size and choose if our mesh should be evenly distributed.
27
00:03:09,779 --> 00:03:20,779
Furthermore, we can adjust the settings for the horizontal and vertical distances.
28
00:03:20,779 --> 00:03:25,500
You will find more information on the settings for the earthing system and on many other
29
00:03:25,500 --> 00:03:32,139
topics in our different tutorials on the e-learning platform.
30
00:03:32,139 --> 00:03:34,899
That's it for this tutorial.
31
00:03:34,899 --> 00:03:35,779
Thanks for watching.